Multiple Instruments with PC Control Software

Product Name : Multiple Instruments with PC Control Software for IoT Devices/ Development Board

Model: LA-MIPCS

Technical Specifications:
Digital Storage Oscilloscope:
 Bandwidth: 100 MHz
 Channels: 2
 Sample Rate: 1 GS/s or higher
 Record Length: 20 K points or higher
 Vertical system – Analog channels:
 Vertical resolution: 8 bits
 Input sensitivity range: 1 mV/div to 10 V/div max.
 DC gain accuracy: ±3.0 % step gain or better
 Maximum Input Voltage: 300 VRMS
 Bandwidth limit: 20 MHz
 Input coupling: DC, AC
 Horizontal system – Analog channels:
 Timebase accuracy: ±25 x 10-6 over any >1 ms interval
 Timebase range: 2 ns/div to 100 sec/div
 Trigger modes: Auto, Normal, Single Sequence
 Trigger Types: Edge, Pulse Width, Runt
 Waveform measurements: Cursors Time,
 Waveform math: Arithmetic, FFT
 Display Type: Minimum 7-inch TFT Color Display
 Display Resolution: 800 horizontal by 480 vertical displayed pixels (WVGA)
 Power source: 100 to 240 VAC RMS ±10%
 Power source frequency: 45 Hz to 65 Hz (100 to
 Power consumption: 30 W

Arbitrary Function Generator:
 Sine frequency range: 1 μHz to 25 MHz or higher
 Square Frequency range: 1 μHz to 20 MHz or higher
 Ramp Frequency range: 1 μHz to 500 kHz or higher
 Pulse Frequency range: 1 mHz to 20 MHz or higher
 Pulse width: 16 ns to 999.99 s or higher
 Pulse width resolution: 10 ps or better
 DC Range: -5 V to 5 V or higher
 Resolution: 1 mV or better
 Accuracy: ± (1% of |Nosting | +1mV)
 Noise Bandwidth (-3 dB): 150 MHz or higher
 Noise type: White Gaussian
 Modulation: AM, FM, PM, FSK, PWM
 Internal modulating frequency: 1 mHz to 1 MHz or higher
 Display: Minimum 9-inch capacitive touch screen with 800 * 480 resolution
 Number of channels: 1
 Run modes: Continuous, Modulation, Sweep and Burst
 Output Characteristics:
 Amplitude range (into 50 Ω): 1 mVP-P to 10`VP-P and (into open circuit or High-Z): 2 mVP-P to 20`VP-P
 Accuracy: ± (1% of Nosting +1 mVP-P)
 Resolution: 0.1 mVP-P, 0.1`mVRMS, 1`mV, 0.1`dBm
 Power source: 100-240 V, 47-63 Hz
 Consumption: 120 W
High Power 3-Channel Programmable Power Supply:
 Number of Channel: 3
 DC Output Rating (for CH 1 and CH 2)-
 Voltage: 0 V to 30 V or higher
 Voltage Limit: 30.1 V
 DC Output Rating (for CH 3)-
 Voltage: 0 V to 5 V or higher
 Voltage Limit: 5.1 V
 Current: 0 A to 3 A
 Maximum power: 195 W
 Load Regulation- Voltage: ≤0.01% + 3 mV and Current: ≤0.01% + 3 mA or better
 Line Regulation- Voltage: ≤0.01% + 3 mV and Current: ≤0.01% + 3 mA or better
 Ripple and Noise: Voltage: 3 mVpeak-peak
 Resolution: Voltage: 1 mV or better; Current: 1 mA or better
 Accuracy: Voltage: ≤0.03% + 10 mV or better; Current: ≤0.1% + 5 mA or better
 Communications: USB, RS232
 Display Vacuum fluorescent display
 Memory 36 Nosup memories
 Power Source: 220 V AC Nosting: 198 VRMS to 264 VRMS, Frequency: 50 Hz, Consumption: 700 VAC

Digital Multimeter:
 15 measurement functions
 5-inch (12.7 cm) multi-touch capacitive touchscreen with graphical display
 Internal memory; store up to 7 million readings
 Standard USB-TMC and LXI/Ethernet communication Interfaces
 USB host port for storing readings, instrument configurations, and screen images
 Cooling Forced air, fixed speed
 DC Voltage Range: 100 mV, 1V, 10V, 100V, 1000V or higher
 DC Voltage Resolution: 100nV ~ 1mV or better
 Resistance Range: 1, 10, 100, 1k, 10k, 100k, 1M, 10M, 100M Ω or higher
 Resistance Resolution: 1 μΩ ~ 100 Ω or better
 DC Current Range: 10 μA ~ 10 A or higher
 DC Current Resolution: 10pA ~ 100 μA or better
 AC Voltage Range: 100mV ~ 750V or higher
 AC Voltage Resolution: 100nV ~ 100 μV or better
 AC Current Range: 100 μA ~ 10 A or higher
 AC Current Resolution: 100pA ~ 10 μA or better
 Frequency and Period Range: 3Hz ~ 300 kHz or higher and 333 ms ~ 3.3 μs or higher
 Capacitance Range: 1 nF ~ 100 μF or higher; Resolution: 0.1 pF ~ 10 nF or better
 Digitize DC Voltage Range: 100 mV ~ 1000 V or higher; Resolution: 10 μV ~ 100 mV or better
 Power Supply: 220 V, 50 Hz
 Power Consumption: 50 VA
Instrument Control Software:
 A software for the PC that enables quick test Nosup and data visualization when using multiple instruments should have
the following features:
 Save time by automating data collection of millions of readings.
 Nos up a multi-instrument test with the ability to independently control up to eight instruments.
 Supports source measure unit (SMU) instruments, DMMs, power supplies, oscilloscopes, arbitrary function generators
(AFGs), dataloggers, and sensitive instruments.
 Replicate tests quickly using saved test configurations.
 Use built-in plotting and comparison tools to quickly discover measurement anomalies and trends.
 Auto-export data in ready-to-use .csv and .xlsx formats for reports and additional analysis.
 Applications-
 Device characterization: Characterize materials and discrete components and verify design of electronic modules.
 Data logging: Reliably log data to the PC; useful for testing device compliance to regulatory or industrial standards.

Request a Free Quote